Low-voltage DC power supply aging test: Designed for DC 12/24/48/52 V switching power supplies, vehicle adapters, industrial DC power modules, and chargers, conducting 24/7 full-load and half-load durability aging verification.
Performance testing of low-voltage batteries: Discharge capacity, cycle life, and internal resistance-discharge curve measurements for lithium-ion batteries, lead-acid batteries, and portable outdoor energy storage battery packs used in low-speed electric vehicles.
Performance acceptance of small power electronic devices: simulation of load operation conditions and output performance verification for low-voltage UPS systems, compact inverters, household micro-energy storage systems, and auxiliary power supplies for low-voltage charging stations.
Reliability testing of industrial control and security equipment: Long-term load-bearing stability tests for security DC power supply devices, industrial control low-voltage DC modules, and communication backup power supplies.
Laboratory Development Calibration: The power supply R&D laboratory simulates multiple levels of variable loads to conduct research and calibration on power output characteristics, protection thresholds, and load-induced voltage dro
Four-level voltage switching: Compatible with DC 12V/24V/48V/52V, covering mainstream low-voltage DC equipment;
High-current tiered capacity: up to 200 A at 52/48 V, 100 A at 24 V, and 50 A at 12 V, with a maximum unit power of 10.4 kW;
Multi-stage precise current regulation with a minimum accuracy of 1 A and resistance accuracy of ±3%, achieving a power factor of 1 for accurate test data;
Equipped with proprietary RCD nonlinear load technology that simulates real-world harmonic loads, ensuring testing conditions closely reflect actual conditions.
Control and safety: buttons + manual contactor operation; digital display shows real-time power, current, and voltage; triple safety features: overtemperature alarm, overvoltage protection, and emergency shutdown to prevent damage to measured equipment and loads; supports 24/7 uninterrupted online operation with a full-year warranty; includes load ports on terminal blocks and a standard AC220V auxiliary power socket for easy wiring.
Q1: Can this load cabinet test multiple voltage devices simultaneously?
A: No, this device is voltage-switching type and can only test at one voltage level (DC 12/24/48/52 V) simultaneously; multiple voltages cannot be operated in parallel.
Q2: Can the device undergo continuous aging for 24 hours without interruption?
A: Supportive design with a 7×24-hour continuous online operation mode and a forced air cooling system, meeting long-term aging requirements for batch power supplies; comes with a 1-year warranty under normal use.
Q3: Is the device only for indoor use? Can it be placed outdoors?
A: Protection rating IP20; suitable only for dry, well-ventilated indoor environments; not recommended for exposure to rain or outdoor use; operating temperature must be maintained between-10°C and 50°C.
Q4: Does the resistance accuracy error affect test results?
A: Resistance accuracy of ±3%, meeting standard aging tests for conventional power supplies and battery discharge tests; high-precision calibration services are available for R&D applications to further reduce errors.
| Model | JH-RYF-200AD52D48-A9A | |
|---|---|---|
| Brand | Jianhong | |
| Dimensions | ≤600*305*610MM(L*W*H) | |
| weight | 28 KG | |
| Rated voltage | DC52V DC48V DC24V DC12V (Switching usage) |
|
| Rated current | maximum 200A for 52V/48V maximum 100A for 24V maximum 50A for 12V |
|
| Auxiliary power supply | AC220V 50Hz-60Hz | |
| Power factor | 1 | |
| Accuracy of resistance | ±3%(Sheet resistor) | |
| Cold mode | Forced air cooling, front to back, 12038 fan Noise ≤90 at one meter |
|
| Work environment | Working environment temperature: -10~50℃, dry and ventilated | |
| Mode of control | Button + contactor | |
| Class of protection | IP20 (Indoor) | |
| Display mode | Digital display power, current, voltage | |
| Adjustable gear | 1A,2A,2A,5A,10A,20A,20A,40A,100A (at DC52V DC48V) | |
| 0.5A,1A,1A,2.5A,5A,10A,10A,20A,50A (at DC24V) | ||
| 0.25A,0.5A,0.5A,1.25A,2,5A,5A,5A,10A,25A (at DC12V) | ||
| Step accuracy | 1A | |
| Load protection | Overheat alarm, overvoltage protection, emergency stop | |
| Way of working | Online continuous work, 7*24 working system, 1 year warranty | |
| Output mode | One set of loads: threaded terminal posts A set of auxiliary power sources: standard power outlets |
|
| Mobility mode | Portable + caster | |