30KW DC100V Resistive Load Bank Portable Adjustable DC Load Bank JH RYF 30KWD100 W10A 300A DC Load Tester For Battery DC Power Source Testing
Product Features Rated power 30KW, rated voltage DC100V, maximum current 300A, power factor 1; Chip resistor is adopted, and the resistance accuracy is 3%. The minimum power adjustment step is 100 w; Multi-gear power segmentation: 100W, 200W, 500W, 1kW, 2kW, 4kW and 10kW. The gears can be superimpos...
Product Features
-
Rated power 30KW, rated voltage DC100V, maximum current 300A, power factor 1; Chip resistor is adopted, and the resistance accuracy is 3%.
- The minimum power adjustment step is 100 w; Multi-gear power segmentation: 100W, 200W, 500W, 1kW, 2kW, 4kW and 10kW. The gears can be superimposed freely, and the load can be set flexibly.
- Forced air cooling, equipped with 15050 fan, the wind direction is from right to left; It can run stably and continuously for 7*24 hours.
- Button control, two-way digital display, which can simultaneously display power, current, voltage and apparent power.
- Multiple safety protection: overheat alarm, overvoltage protection (the maximum voltage is 1.1 times the rated voltage) and emergency stop button.
Application Scenarios
-
DC battery pack discharge test and battery capacity detection
-
Performance test of DC power supply, DC UPS and rectifier
-
DC power supply aging test, factory routine load test
- Simulation load test of DC side of energy storage
-
Research on DC output verification of generator and laboratory power supply
Common Questions & Answers
Q1: What is the minimum adjustable power step?
A: The minimum step is 100W, and all power gears can be superimposed freely.
Q2: Can the equipment run continuously for a long time?
A: Yes, it supports 7*24 hours online continuous work under normal working conditions.
Q3: What are the protection functions?
A: Built-in overheat alarm, overvoltage protection (up to 1.1 times the rated voltage) and emergency stop button ensure safety.
Q4: What is the protection level?
A: IP20, only suitable for indoor dry and ventilated environment.
Q5: What kind of cooling method is used?
A: Forced air cooling, using 15050 cooling fan, the wind direction is from right to left.
| Product parameters | ||
|---|---|---|
| Model | JH-RYF-30KWD100-W10A | |
| Brand | Jianhong | |
| Dimensions | ≤400*550*770MM(L * W * H) | |
| weight | ≤50KG | |
| rated voltage |
DC100V |
|
| rated power | 30KW | |
| maximum current | 300A | |
| accessory power supply | AC220V 50HZ | |
| power factor | 1 | |
| Resistance accuracy |
±3%(Sheet resistor) |
|
| Cold mode |
Forced air cooling, from right to left, 15050 fan |
|
| Work environment |
Working environment temperature: -10~50℃, dry and ventilated. |
|
| Local control mode | push-button control | |
| Class of protection | IP20 (Indoor) | |
| display mode |
Two channels of digital display power, current, voltage and apparent power. |
|
|
Power grading |
100W,200W,200W,500W,1KW,2KW,2KW,4KW,10KW,10KW(Can be superimposed) | |
|
Stepping accuracy |
100W | |
| Load protection |
Overheating alarm, overvoltage protection (the maximum voltage is 1.1 times the rated voltage), and emergency stop. |
|
|
working |
Can work continuously online, with 7*24 working system and 1 year warranty. |
|
|
Load input method |
A set of resistance outgoing lines: threaded terminals A set of auxiliary power supply: standard socket |
|
|
Mobile mode |
Hand+caster | |