Customizable Resistive Load Bank Designed to Meet Various Electrical Load Testing and Performance Verification Needs
One-line Pitch A 3 kW, 8-step resistive load bank in a 29 kg portable cabinet: dial in any load from 40 W to 3 kW, watch voltage, current and power on the built-in meter, and load-test UPS units, inverters and generators right on the bench. Product Features 1.1 40 W Steps up to 3 kW — Load You Can ...
One-line Pitch
A 3 kW, 8-step resistive load bank in a 29 kg portable cabinet: dial in any load from 40 W to 3 kW, watch voltage, current and power on the built-in meter, and load-test UPS units, inverters and generators right on the bench.
Product Features
1.1 40 W Steps up to 3 kW — Load You Can Actually Dial In
Eight independent resistance steps — 40 W, 60 W, 100 W, 100 W, 200 W, 500 W, 1 kW and 1 kW — add up to a full 3 kW, so any point from 40 W to 3 kW can be reached in 40 W increments instead of coarse 500 W or 1 kW jumps. Sheet resistors are held to ±3% tolerance and power factor is 1, so the load is purely resistive: the power your meter reads is real power, with no reactive component to explain away.
1.2 4U Cabinet, 29 kg — One Person Can Carry It
530 × 200 × 430 mm and ≤ 29 kg, with a top carry handle and rubber foot pads: lift it out of the van, set it beside the cabinet under test, and start loading. The 4U-height chassis also fits standard racks and test benches, so the same unit works in the lab, on the production line and on site.
1.3 Digital Meter + Breaker-per-Step: No Firmware, No Firmware Faults
Voltage, current and power read out live on the digital display while you load. Each step has its own manual air circuit breaker — loading is a physical switch, not a menu. There is no controller, no communication protocol and no configuration file to go wrong, which is exactly what you want in a verification tool that must give the same answer every time.
1.4 Forced Air Cooling + Dual Protection — 4 Hours at Full Load
A 15050 fan (220 VAC) pushes air front-to-back through the chassis, and over-temperature plus over-voltage protection watch the unit while it runs. Rated for 4 consecutive hours at full power in −10 to 50 °C, dry and well-ventilated surroundings, IP20 for indoor use, with a 1-year warranty.
Application Scenarios
2.1 UPS & Inverter Load Testing
2.2 Generator & Standby Power Maintenance
2.3 Power Supply R&D and Production QC
2.4 Burn-in Rooms, After-sales Repair and Training
FAQ
Q1 How do I set an exact load value?
Combine steps. Each breaker adds a fixed resistance, so loads add up: 1.5 kW = 1 kW + 500 W; 1.36 kW = 1 kW + 200 W + 100 W + 60 W; 3 kW = all eight steps on. Because the smallest step is 40 W, most practical test points are reachable without approximation.
Q2 How long can it run continuously, and what cooling clearance does it need?
4 consecutive hours at rated power, with forced front-to-back air cooling from the 15050 fan. Keep the front intake clear (at least 0.5 m of free space is recommended by the panel warning label) and install it in a dry, well-ventilated place between −10 and 50 °C. It is an indoor unit (IP20), not a weatherproof enclosure.
Q3 What is the resistance tolerance — and if I need tighter accuracy?
±3% on sheet resistors, with power factor 1, so the displayed power tracks the actual resistive load closely. For calibration work that needs a certified reading or a tighter tolerance, tell us the target figures and we will confirm what can be done for your case.
Q4 How is it wired, what is included, and can it be customised?
Two connections: the auxiliary power inlet (standard power socket, AC 220 V 50 Hz) powers the fan and meter; the load output is one set of resistor cabling terminated in an Anderson connector, which hooks straight onto the terminals under test. Standard build is AC 220 V / 50 Hz, 3 kW, with the eight steps above and a 1-year warranty. If your market runs 110 V / 60 Hz, or you need a different power or step split, send us the requirement and we will confirm feasibility before quoting.
| Model name | JH-RYF-3KWA220-W8K |
| Brand | JIANHONG |
| Specification | 530 × 200 × 430(L*W*H) |
| Weight | ≤ 29 kg |
| Rated voltage | AC 220 V |
| Rated power | 3 kW |
| Auxiliary power supply | AC 220 V, 50 Hz |
| Power factor | 1 |
| Resistance accuracy | ±3%(Sheet resistor) |
| Cooling system | Forced air cooling, front-to-back airflow, 15050 fan (220 VAC power supply) |
| Working environment | Operating temperature: -10 to 50 °C; dry and well-ventilated |
| Control mode | Manual air circuit breaker |
| IP class | IP20 (indoor environment) |
| Display mode | Digital display of voltage, current and power |
| Adjustable Steps | 40 W, 60 W, 100 W, 100 W, 200 W, 500 W, 1 kW, 1 kW |
| Load protection | Over-temperature protection, over-voltage protection |
| Working mode | Continuous online operation, 4-hour duty cycle; 1-year warranty |
| Movement method | Carry handle + foot pads |
| Output | 1 set of resistor output cable (Anderson connector) + 1 set of auxiliary power supply (standard power socket) |