Resistive Load Bank Offering Flexible Load Configurations And Performance For Testing Various Electrical Power Equipment
One-line Pitch An 80 kW, DC 800 V adjustable load bank rated to 1000 V: 5 A-step current setting with 18 fans of front-to-rear forced cooling, continuous 7×24 duty, and a 146 kg wheeled cabinet that can be rolled to the equipment under test. Product Features 1.1 800 V Rated, 1000 V Capable Rated DC ...
An 80 kW, DC 800 V adjustable load bank rated to 1000 V: 5 A-step current setting with 18 fans of front-to-rear forced cooling, continuous 7×24 duty, and a 146 kg wheeled cabinet that can be rolled to the equipment under test.
Rated DC 800 V with a maximum of DC 1000 V, so the bank can follow an 800 V DC source through its whole operating window instead of sitting below it. Power factor 1 means the load is purely resistive and the meter reads real power, while resistance tolerance of ±1% is tighter than the ±3% common on general-purpose banks — useful when the measured efficiency figure has to hold up.
The load is specified and set in amps rather than watts, which matches how chargers, battery packs and DC sources are actually rated. Seven power steps — 5 A, 5 A, 10 A, 20 A, 20 A, 20 A, 20 A — are combined to reach the target current, with 5 A resolution, so a 55 A point is simply 20 + 20 + 10 + 5 A.
Eighteen 15050 fans (AC 220 V) pull air in at the front and push it out the back, which is what allows 80 kW of dissipation in a 700 × 600 × 1520 mm cabinet weighing 146 kg. Rated for continuous online operation on a 7×24 duty cycle, so burn-in and long soak tests do not have to be split into sessions.
Control is by push buttons and the DC smart meter shows voltage, current and power directly — no software to configure before a test. Load is taken out through a set of copper busbars, auxiliary power through a TB2504 terminal block. Over-voltage protection, over-temperature alarm and an emergency stop are built in, the enclosure is IP20 for indoor use, and the warranty is 1 year.
Rated DC 800 V, maximum DC 1000 V, rated power 80 kW, power factor 1. At rated voltage the load current is about 100 A (80 kW ÷ 800 V, calculated), which matches the stated 5–100 A adjustable range. Operating environment is −10 to 50 °C, dry and well-ventilated, IP20 indoor.
By combining power steps in 5 A increments within the 5–100 A range. The seven steps are 5 A, 5 A, 10 A, 20 A, 20 A, 20 A and 20 A, so any multiple of 5 A can be assembled — 45 A = 20 + 20 + 5 A, 55 A = 20 + 20 + 10 + 5 A. Current carrying capability is verified on the DC smart meter while the test runs.
Control is local, by push buttons on the front panel — no external controller or software is needed to start a test. The DC smart meter displays voltage, current and power. If your project needs the load driven from a PLC or an automated test sequence, tell us the interface you work with and we will confirm what can be arranged.
Eighteen 15050 fans (AC 220 V) move air front to rear, so both faces must stay unobstructed; install indoors in a dry, well-ventilated place. Protection covers over-voltage, over-temperature alarm and emergency stop, and the unit is rated for 7×24 continuous online operation with a 1-year warranty. Load is taken from a set of copper busbars, auxiliary power from a TB2504 terminal block; the cabinet moves on casters.
| Model name | JH-RYF-80KWD800-A7A |
| Brand | JIANHONG |
| Specification | ≤ 700 × 600 × 1520 mm (L × W × H) |
| Weight | 146 kg |
| Rated voltage | DC 800 V (max. DC 1000 V) |
| Rated power | 80 kW |
| Auxiliary power supply | AC 220 V – AC 250 V, 50/60 Hz |
| Power factor | 1 |
| Resistance accuracy | ±1% (sheet resistor) |
| Cooling system | Forced air cooling, front-to-rear airflow, 18 × 15050 fans (AC 220 V) |
| Working environment | Operating temperature: −10 to 50 °C; dry and well-ventilated |
| Control Method | Push buttons |
| IP class | IP20 (indoor use) |
| Display mode | DC smart meter (voltage, current, power) |
| Adjustable Steps | 5 A steps, adjustable from 5 A to 100 A Power steps: 5 A, 5 A, 10 A, 20 A, 20 A, 20 A, 20 A |
| Load protection | Over-voltage protection, over-temperature alarm, emergency stop |
| Duty Cycle | Continuous online operation, 7×24 duty; 1-year warranty |
| Output | 1 set of copper busbars + 1 set of auxiliary power (TB2504 terminal block) |
| Mobility | Casters |