The Manually Controlled 10KW RCL Load Bank Is Used For Power System Load Testing
Product Features
Manual control mode
It is controlled by manual adjustment, and multiple switches can be used to switch different values of resistance, inductance and capacitance.
High precision and stability
The 10KW RCL load bank adopts high-quality resistors, inductors and capacitors inside to ensure the accuracy and stability of load parameters. Manual adjustment is convenient for users to set the target parameters. Meanwhile, a heat dissipation design is adopted to effectively prevent excessive temperature rise caused by continuous high-power operation, thereby ensuring the safe and stable operation of the load.
Monitoring and security protection
Although the 10KWRCL load bank is manually controlled, it is equipped with multiple safety protection measures, including overload protection, short-circuit protection and overheat alarm. When the equipment detects an abnormal state, it automatically cuts off the power supply or issues a warning to ensure the personal safety of the operators to the greatest extent and the normal operation of the equipment.
Product parameters
Model number | JH-RCL-10KWA220A110-W13K |
|||||
brand | jianhong |
|||||
dimension | 600*700*1550MM(D*W*H) |
|||||
weight | ≤150KG |
|||||
Rated voltage | AC220V/AC110V Switch use |
|||||
Rated power | R:10KW C:10KVA L:10KVA |
|||||
Auxiliary power supply | AC220V |
|||||
Power factor | tunable |
|||||
Resistance accuracy | ±3%(High precision, small volume, ultra-light resistance is used in the load box) | |||||
Cooling system | Forced air cooling, forward and back out,15050AC220 fans 6 | |||||
Working environment | Working temperature: -10~50℃, dry, well ventilated | |||||
Control mode | Circuit breaker control | |||||
IP level | IP20(Indoor environment) | |||||
Display mode | Display load voltage, current, power, frequency, power factor, etc. (switching) |
|||||
Power rating | R-load 220V:1W,2W,2W,5W,50W,50W,100W,100W,200W,500W,1KW, 2KW,2KW,4KW, R-load 110V:0.25W,0.5W,0.5W,1.25W,12.5W,12.5W,25W,25W, 50W,125W,250W,500W,500W,1KW,2.5KW,2.5KW,2.5KW The R-load has four more small power gears (red font) than the C-load and L-load, and the rest are the same |
|||||
Load protection | High temperature alarm, fault alarm, emergency stop, sound and light prompt, working status indication |
|||||
Working mode | Continuous online work, 7*24 working system, resistance life of 15 years |
|||||
Moving mode | Bipedal type |
The 10KW RCL load box is widely used in industries such as power, electronics and communications.
Application scenarios include:
Output load performance test: Verify the capabilities of the power supply, inverter and converter
Fault simulation: Simulate different types of load conditions to test the adaptability and safety of the equipment
R&d verification: During the new product development process, various working condition tests and analyses are conducted
Maintenance and repair: On-site equipment inspection to ensure normal operation of the equipment