4KW 54V DC Adjustable Resistive Load Bank For UPS Battery Power Supply Testing
The JH-RYF-4KWD54-W6K-JJ represents the gold standard in industrial-grade rack-mounted load bank solutions, designed for mission-critical power testing applications. As a rack-mounted load bank, it delivers 4kW of precision DC loading capacity within a compact 19-inch chassis (485×450×177mm), making it ideal for data centers, marine power systems, and telecom installations where space optimization is crucial.
This rack-mounted load bank features six manually-switched power stages (400W×2 + 800W×4) with ±5% current accuracy, allowing engineers to simulate real-world load conditions from 400W to 4kW. The rack-mounted load bank's ultra-thin resistor array maintains <350℃ surface temperature at full load, supported by IP20-rated enclosure with <35℃ external temperature rise - a testament to its superior thermal management as a rack-mounted load bank.
Precise Load Simulation: The JH-RYF-4KWD54-W6K is designed to simulate various load conditions encountered by uninterruptible power supplies (UPS). It allows accurate testing and validation of UPS systems.
Adjustable Load Levels: With its adjustable load capacity ranging from 1KW to 4KW, this load bank accommodates different load scenarios. Engineers can fine-tune the load to match specific UPS requirements.
Real-time Monitoring: Equipped with a display panel, it provides real-time monitoring of load current, voltage, and frequency. This feature aids in assessing UPS performance during testing.
Stability and Safety: By applying controlled loads, the JH-RYF-4KWD54-W6K ensures stable UPS operation and prevents voltage fluctuations. It contributes to system reliability.
Compact and Portable: Its compact form factor allows easy integration into testing setups. Additionally, the load bank’s portability facilitates on-site testing and maintenance.
Model name |
JH-RYF-4KWD54-W6K-JJ |
Dimensions |
485*450*177mm |
Rated power | 4KW |
Rated current |
74A |
Adjustment gear |
400W 400W 800W 800W 800W 800W |
Load bank resistance | Ultra-thin resistor (accuracy error ±5%) |
Test voltage | Less than or equal to 54V DC |
System power supply |
AC220V 10A |
Resistance surface temperature rise |
<350℃ (Temperature rise at full power) |
Box surface temperature rise |
<35℃ |
IP class |
IP20 |
Voltage of insulation |
≥3kv |
As a rack-mounted load bank, it serves vital roles in:
Generator performance validation (marine/aviation)
Data center UPS load testing
Renewable energy storage evaluation