Product Features
1. Compatible with AC 110 V/AC 220 V dual-voltage switching, suitable for voltage testing requirements in multiple countries
2. 10.5 kW rated resistive load, 10 freely combinable settings, 50 W fine adjustment
3. High-precision resistors, power factor of 1, stable load output
4. Manual control of the circuit breaker; the digital display panel shows voltage, current and power simultaneously
5. Forced air cooling with air intake at the bottom and exhaust at the top, ensuring stable and long-lasting heat dissipation
6. Incorporates multiple safety protections, including overheating alarm, emergency stop and overvoltage protection
7. Fitted with castors for easy on-site repositioning
Application Scenarios
Factory ageing and performance testing of UPS units, inverters and power modules
Load testing of the output from the variable-frequency power supply and shore power supply
Research, development and commissioning of laboratory power supplies; type testing
Sampling tests on production lines, batch ageing verification
Common Questions & Answers
Q1: Can 110V and 220V be used at the same time?
A: No, as it is a switching design, it only supports operation at one voltage at any given time.
Q2: What is the maximum power input?
A: The maximum combined power at full load is 10.5 kW; prolonged operation in excess of the rated power is not recommended.
Q3: Can it be used outdoors?
A: Protection rating IP20; for use in dry, well-ventilated indoor environments only; not suitable for outdoor use.
Q4: When is the overvoltage protection triggered?
A: Overvoltage protection is automatically activated when the voltage reaches 1.1 times the rated voltage.
Q5: Does it support continuous operation over long periods?
A: Under rated operating conditions, it can operate continuously 24 hours a day, 7 days a week, and is equipped with comprehensive cooling and protection mechanisms.
| Product parameters | ||
|---|---|---|
| Model | JH-RYF-10.5KWA110A220-W10K | |
| Brand | Jianhong | |
| Dimensions | 600*400*650MM (depth × width × height) | |
| weight | 45KG | |
| rated voltage |
AC110V/AC220V Switch to |
|
| rated power |
|
|
| accessory power supply | AC220V | |
| power factor | 1 | |
| Resistance accuracy |
±3% (the load box uses a new type of resistor with high precision, small volume and ultra-light weight) |
|
| Cold mode |
Forced air cooling, lower inlet and upper outlet, 200*60 fans *2. |
|
| Work environment |
Operating temperature: -10 to 50 °C, dry and well-ventilated |
|
| Local control mode | Manual idle control | |
| Class of protection | IP20 (Indoor) | |
| display mode |
It can display load voltage, current and power at the same time. |
|
|
Power grading |
|
|
|
Stepping accuracy |
50W |
|
| Load protection |
Overheating alarm, emergency stop and overvoltage protection (the maximum voltage is 1.1 times the rated voltage) |
|
|
working |
Continuous on-line operation, 7*24 working system, resistance service life of 15 years, one-year warranty. |
|
|
Load input method |
Threaded terminal | |
|
Auxiliary power input mode |
Standard power socket | |
|
Mobile mode |
Caster type | |